How to Choose a Power Supply for Packaging Machines: Servo Start-Stop, Seal-Bar Heating and Dust

How to Choose a Power Supply for Packaging Machines: Servo Start-Stop, Seal-Bar Heating and Dust

One-line answer: in nine out of ten cases a packaging machine burns supplies not because there is too little power, but because the servos, the seal-bar heaters and the control circuit are hung on one supply. Split those three circuits, size by "peak axes x per-axis power" rather than average power, and fit a filter on the servo and heater circuits — the failure rate drops sharply.


1. Why packaging machines are hard on supplies: three overlapping characteristics

Packaging machines (pillow-type, vertical form-fill-seal, pouch, seal-cut, labelling, filling) look like light loads, but they are one of the harshest applications for a power supply:

CharacteristicWhat it looks likeWhat it demands from the supply
High-frequency start-stop30-150 packs/min, each pack 2-4 accel/decel cyclesInstantaneous current 3-5x the average
Multiple axes moving togetherFilm feed, film pull, sealing, discharge, 3-6 axes interlockedPeaks add up, DC bus dips
Large resistive loadSeal-bar heater 200-800W, permanently onCompetes with servos for the same supply

Add the real workshop conditions — dust in powder filling, washdown water in food plants, static from film — and you have the full explanation for "the supply bulged after a year".


2. Five real causes

2.1 Servos, heaters and controls sharing one supply (most common, most damaging)

A typical wiring: one 600W/24V supply feeding three servos (24V or 48V), the PLC, the HMI, sensors, and two seal-bar temperature loops.

The problem is that these three load types behave in opposite ways:

  • Servos: pulsed current draw, pulling most of the power during acceleration, and regenerating energy during deceleration which raises the bus;
  • Heaters: purely resistive, continuously at full load, power factor near 1, but cold resistance is one tenth of hot resistance, so inrush at switch-on is enormous;
  • Control system: low power but highly sensitive to voltage fluctuation — a 10% dip can cause a reset.

The result: the servo accelerates, the bus drops to 20V and the PLC resets; the servo decelerates, the bus spikes to 28V and the capacitors see overvoltage. The supply is not defective — it is being abused.

Fix: three separate circuits. One for control, one for servos (or grouped by axis), and heaters fed directly from 220V without going through a switching supply. Do this one thing and the failure rate drops by an order of magnitude.

2.2 Sizing by average power and ignoring peak stacking

The nameplate figure on a packaging machine is usually an average, while simultaneous servo acceleration can reach 3-5x.

Sizing formula:

`` Required power = SUM(rated power of each axis) x simultaneity factor (0.7-1.0) x 1.3 ``

How to set the simultaneity factor: if all axes really do accelerate together (film feed plus seal-cut on a pillow machine), use 1.0; if they are sequential (feed, seal, discharge), use 0.7.

Do not estimate as "total motor power x 0.8" — that is badly undersized.

2.3 Servo regeneration with no bleed path

Packaging servos accelerate and decelerate dozens of times a minute, and every deceleration pumps kinetic energy back into the 24V/48V bus. Without a braking resistor or regenerative unit the bus repeatedly spikes, overvoltage protection keeps tripping, and the output capacitors take repeated reverse stress.

Symptom: "supply used for six months, output capacitors bulged".

Fix: fit a braking resistor on the servo drive (most drives have brake terminals, only an external resistor is needed); for multi-axis systems consider a common DC bus so decelerating energy feeds accelerating axes.

2.4 Dust blocking cooling and driving temperature out of control

Powder filling (milk powder, protein powder, flour, pesticide powder) produces extremely fine dust that passes ordinary filters and settles on heatsink fins and PCBs. Dust is also hygroscopic, and once damp it forms weak conductive paths that accelerate failure.

Symptom: "clustered failures in summer, white powder inside every unit".

Fix: install the supply in a positive-pressure zone of the cabinet with filter media at the intake; prefer fanless models (no fan means no active dust intake); blow down quarterly.

2.5 Film static and poor grounding

Packaging film (PE/PET/aluminium laminate) generates large static charges at high line speed, reaching several kilovolts. Discharge through the frame and sensor cables damages PLC inputs and disturbs load-cell signals.

Symptom: "weight readings jumping, photo-eye false triggering, burnt PLC inputs".

Fix: reliable single-point grounding of the machine (ground resistance <4 ohm — not "bolted to the frame"); add static eliminator bars or ionised air along the film path; use shielded cable for sensors and signal lines with the shield grounded at one end.


3. How to select: match the machine class

Machine classTypical configurationRecommended supplyNote
Small machines (labellers, case erectors, single-axis seal-cut)24V control + 1-2 axesFYDR-240-24 / FYDR-350-24 / FYDR-480-24 (DIN rail, 92%)Slim DIN-rail mount, saves cabinet space, single 24V rail is enough
Medium pillow/vertical machines24V control + 3-5 servo axesControl: FYD-600-24P / FYD-800-24P / FYD-1200-24P; servo: FYD-600-48P / FYD-1500-48PFlat-pack, cabinet-mount; 48V servo on its own circuit
Machines needing 5V/±15V (weighing, analogue, display)24V+5V+±15VFYD-400QLB-S (24V/5V/±15V), FYD-600QLB-SMulti-output isolated rails, load cell separated from digital ground
Large lines (multiple machines, central cabinet)1000W+ central supplyFYDG-600-24 / FYDG-1000-24 / FYDG-2000-24380V direct input, no control transformer
48V high-power servo/drive2000-3000WFYD-2000-48P / FYD-3000-48DOne high-power unit beats several paralleled

Four packaging-specific rules:

  1. Control, servo and heater must be three separate circuits — the most important rule here, more important than any model choice;
  2. Give the servo circuit its own supply and size it as "axes x per-axis power x simultaneity factor", never by average power;
  3. Do not run heaters through the switching supply — feed them from 220V through solid-state relays or a temperature controller (cheaper and one less failure point);
  4. Derate for 45-50 C inside the cabinet — packaging cabinets also contain servo drives, so it is hotter than you think.

4. Filters: packaging machines need only two, but they must be installed correctly

LocationSelectionNote
Machine 220V feed (when control and servo share the feed)FYL-3N-10A-U / 20A-U / 30A-U (single-phase two-stage, terminal block)Grade at 1.2x the machine feed current
Servo drive inputFYL-3N-06A-U / 10A-U or FYL-5N-03A-L / 06A-L (leaded)One per drive, mounted close to the drive
Small three-phase feed (whole line below 3.7kW)FYLn-10D-10A-U / 20A-U (three-phase single-stage)Grade by feed current
Export machines needing CE/EMCFYLn-12N-20A-U / 14N-40A-U (three-phase two-stage)Two-stage gives higher high-frequency insertion loss

Three installation rules:

  1. Mount at the machine inlet or drive input with leads <30cm;
  2. Bond the case to the cabinet ground bar with the shortest, thickest conductor — not to a painted door;
  3. Route filter input and output separately — no parallel runs, no bundling.

5. The five pitfalls, as a self-check

#PitfallWhat you see on siteCorrect practice
1Servo + heater + control on one supplyPLC resets during acceleration, bulged capacitorsThree separate supplies
2Estimating capacity as total motor power x 0.8Overload protection at start-upAxes x per-axis power x simultaneity x 1.3
3No braking resistor on servosBulged output capacitors and overvoltage alarms within six monthsExternal braking resistor at the drive
4Supply mounted in the direct dust pathClustered summer failures, dust insidePositive-pressure cabinet with filter media, fanless models
5Bonded to the frame only, no real groundWeight readings jumping, photo-eye false trips, burnt inputsSingle-point ground <4 ohm, shield grounded one end, static elimination

6. FAQ

Q1: 24V or 48V servos for a packaging machine? A: It depends on axis power. Small axes (below 400W) are fine at 24V with simpler wiring; above 400W, 48V is better — half the current for the same power means lower line loss and less heat, a clear advantage over long runs. Do not mix 24V and 48V servos on one machine; it adds another supply and another set of spares.

Q2: How many servo axes can one 600W supply drive? A: You cannot simply divide 600W by per-axis power. Servos are pulsed loads; the practical rule is to keep total power below 60-70% of the supply rating and check how many axes accelerate together. Three 200W axes accelerating simultaneously can already exceed 600W at the peak.

Q3: Why should seal-bar heaters run on 220V separately? A: Two reasons: (1) a heater's cold resistance is one tenth of hot resistance, so switch-on inrush is about ten times rated current and will repeatedly trip overcurrent protection if fed from a switching supply; (2) heating is a large purely resistive load that permanently occupies capacity, leaving no margin for servos and controls at peak.

Q4: Does a packaging machine supply need PFC? A: Machines exported to the EU must have it (EN 61000-3-2 sets harmonic limits above 75W); for domestic sales it depends on the customer. PFC models reach a power factor above 0.95 and are friendlier to other equipment on the same grid.

Q5: Why does a new machine run fine, then start eating supplies after a year? A: Three cumulative factors: (1) dust builds up on heatsink fins and temperature rise increases year on year; (2) electrolytic capacitors age naturally and lose surge capability as capacitance falls; (3) without a braking resistor the capacitors have already taken a year of reverse stress. Together, one year is the tipping point.

Q6: A food plant washes the floor — what IP rating is needed? A: Take the cabinet to IP54 or better and keep the supply inside, not directly washed. If it must be exposed, choose a higher IP rating and mount with terminals facing down to avoid pooling. Note that IP only guarantees against water jets, not against condensation in prolonged high humidity; an anti-condensation heater is still recommended.


7. Selection checklist

  1. List the three load types: control 24V / servo 24V or 48V / heating 220V — supply them separately;
  2. Size servos as "SUM per-axis power x simultaneity (0.7-1.0) x 1.3" and controls as "maximum current with all loads active x 1.5";
  3. Derate for 45-50 C inside the cabinet (85% at 45 C, 75% at 50 C);
  4. Where weighing or analogue signals exist, choose isolated multi-output (FYD-400QLB-S / 600QLB-S);
  5. Fit one single-phase two-stage filter (FYL-3N series) at the machine feed and one at each servo drive;
  6. Fit external braking resistors on servo drives; consider a common DC bus for multi-axis systems;
  7. Cabinet positive pressure + filter media + single-point ground <4 ohm + static elimination along the film path.

Related product pages: 24V switching power supplies | 48V switching power supplies | DIN-rail power supplies | Two-stage filters | Single-phase filters

Shanghai FONYUN Industrial Co., Ltd. — manufacturer of switching power supplies and EMI filters, with DIN-rail, flat-pack, isolated multi-output and 380V-input ranges, supplying packaging, food and labelling machinery, and calculating selections against axis count and operating conditions.

Technical basis for this article was compiled by the FONYUN technical support team. Complete power solutions and sample testing for packaging machines are available on request.